Test ID: Z4541

Free Digoxin

  • CPT Code: 82130
  • LOINC: 3562-6
  • Specimen Type: Red or SST
  • Frequency: Setup: Daily; Analytic time 1 day
  • Instructions: 1.0mL serum from red or SST tube, refrigerate. Min 0.5mL. Draw 6-8 hrs after last dose of Digoxin.
  • Text: Useful for evaluating recrudescent digoxin tosicity in renal failure patients; Assessing the need for more antidigoxin Fab to be administered; Deciding when to reintroduce digoxin therapy; Monitoring patients with possible digoxin-like immunoreactive factors (DLIFs).
  • Methodology: Ultrafiltration followed by Electrochemiluminescent Immunoassay.

 